Home Solar, Batteries & Energy
Solar panels and inverters, home batteries and portable power stations, heat pumps, dynamic tariffs, export payments and DIY systems, alongside energy markets and climate policy.
About this list
English coverage of home energy equipment, DIY systems, markets and climate policy. Check the country and product context of every source; manufacturer channels provide commercial viewpoints.
Stories from Solar DIY - Do-it-yourself solar projects! [Reddit]. Show all stories · All sources
Latest stories
Newest first
Updates are delayed. Showing the last checked articles.
Solar system provides the correct voltage, and the MPPT detects the solar input, but it does not charge the battery
My problem: The integrated charge controller does not charge the battery, even though it detects that solar panels are connected. My setup: Solar panels: - 2 × 100 W solar panels connected in series - Voc: 22.58 V - Vmp: 19.34 V Inverter / all-in-one unit: - Active SSI 10 (older model) - 550 W / 70 V - Integrated MPPT solar charge controller Battery (brand new): - 200 Ah, 12 V LiFePO₄ (lithium iron phosphate) Measured voltage at the solar charge controller:
DC to DC charging
I have a van converted for camping while fishing that runs off roughly 15kw of 12v lithium with solar charging. My question is what is the most efficient or best way to recharge a 12v trolling motor battery that I have used throughout the day? Meaning I can’t use the solar to recharge it overnight for fishing the next day. Feels like using the inverter to run a 120v charger to do it insane. Both the house bank and trolling battery are LiPo4 12v Thanks submitted by /u/Agreeable_Button7385 [link] [comments]
Severe Grid Overvoltage (270V+) on 5.85 kW On-Grid Solar in AP, India (APCPDCL) – Service wire upgrade vs. Discom transformer tap setting?
I installed a 5.85 kWp rooftop system (10 × 585 W panels, Deye 5 kW single-phase on-grid inverter) under PM Surya Ghar in September. Single-phase supply, net metering with APCPDCL, in a village in Parchur mandal, AP, India. The problem: at midday the voltage at my inverter goes very high when it exports at full power. 4.8 kW / 16.9 A export → 277.6 V 4.98 kW / 17.9 A export → 270.8 V About 2 V rise for every amp exported Street voltage itself seems to drift from about 235 V to 246 V between 11 AM and 1 PM
Growatt SPM 6000TL-HU – app/manual mismatch, commissioning currently broken
I recently installed a Growatt SPM 6000TL-HU with a Growatt HOPE battery. The inverter itself works fine locally: charging, backup mode and BMS communication are all OK. The problem is the software/commissioning. My supplied manual says the SPM can be commissioned through internal Bluetooth using ShineTools, then connected to Wi-Fi. In the current ShineTools 3.6.7.0, SPM 6000TL-HU is not even available in the Direct WiFi/Bluetooth device list.
You have reached the end of this list.
Showing 4 of 4 articles